xmipp3.protocols.protocol_movie_dose_analysis module
- class xmipp3.protocols.protocol_movie_dose_analysis.XmippProtMovieDoseAnalysis(**args)[source]
Bases:
ProtProcessMoviesAnalyzes the electron dose applied throughout a movie acquisition. This protocol helps assess dose accumulation and its effects on image quality, providing information essential for dose weighting and optimizing reconstruction.
AI Generated
## Overview
The Movie Dose Analysis protocol evaluates whether the electron dose in a set of movies is consistent across the acquisition.
In cryo-EM, the electron dose per frame is a key acquisition parameter. If the dose is too low, the frames may have insufficient signal for reliable alignment and later processing. If the dose is too high, the specimen may suffer stronger radiation damage. More importantly for this protocol, if the dose changes unexpectedly during data collection, some movies may not be directly comparable with the rest of the dataset.
This protocol estimates an experimental dose value for each movie by measuring the average intensity in selected frames. It then compares each movie with a global reference dose. Movies whose estimated dose differs too much from the reference are separated into a discarded output set, while movies within the accepted interval are kept in the accepted output set.
The protocol is therefore a quality-control step for detecting possible dose inconsistencies, acquisition instabilities, or incorrectly recorded dose metadata.
## Inputs and General Workflow
The main input is a set of movies.
For each movie, the protocol reads a few representative frames and estimates the mean dose per square angstrom from their average image intensity and the movie sampling rate.
After enough movies have been processed, the protocol estimates a global reference dose. If a dose per frame is available in the acquisition metadata, the protocol compares it with the experimentally estimated dose. If the two values are compatible, the metadata value is used. If they differ too much, the protocol uses the experimental median instead.
Each movie is then compared with the global reference dose. Movies inside the allowed percentage interval are accepted. Movies outside the interval are discarded.
The protocol also generates dose-analysis plots showing dose values and dose differences over time.
## Input Movies
The Input movies parameter should point to the movie set to be evaluated.
The protocol assumes that the movie files can be read frame by frame. For each movie, it reads representative frames from the beginning, middle, and end of the exposure, and uses their mean intensity to estimate dose-related statistics.
The input movie set may be static or streaming. In streaming mode, the protocol updates its analysis as new movies arrive.
This protocol does not align movies and does not correct them. It only evaluates dose consistency.
## Experimental Dose Estimation
For each movie, the protocol estimates the mean dose from selected frames.
Conceptually, it reads three frames:
the first frame;
a middle frame;
the last frame.
For each frame, it computes the mean pixel value and converts it into an estimated dose per square angstrom using the sampling rate. The protocol then computes basic statistics across these frame estimates: mean, standard deviation, minimum, and maximum.
The resulting mean value is used as the movie-level dose estimate.
This is a practical quality-control estimate. It is not intended to replace a full physical detector calibration, but it can detect strong inconsistencies in dose behavior across a dataset.
## Global Reference Dose
The protocol needs a global reference dose to decide whether each movie is consistent with the dataset.
If the input movie metadata contain a valid dose-per-frame value, the protocol initially considers this value as the expected reference. However, it also estimates an experimental median dose from a sample of movies.
If the metadata dose and the experimental median agree closely, the metadata dose is used as the reference. If they disagree beyond an internal tolerance, the protocol switches to the experimental median and reports that the provided dose per frame does not match the measured one.
This behavior is useful because dose metadata may sometimes be missing, incorrect, or inconsistent with the actual recorded images.
## Samples to Estimate the Median Dose
The Samples to estimate the median dose parameter defines how many movies are used before the protocol establishes the initial experimental global median.
By default, the protocol waits until 20 movies have been measured. This avoids making acceptance decisions from too few examples.
A larger value gives a more stable estimate of the global dose, but delays the start of accepted/discarded output production. A smaller value allows earlier classification of movies, but the reference dose may be less robust.
In streaming workflows, this parameter is especially important because the protocol must estimate the reference dose while data are still arriving.
## Maximum Percentage Difference
The Maximum percentage difference parameter defines the accepted interval around the global reference dose.
For example, with a value of 5%, a movie is accepted if its estimated dose is within ±5% of the global reference dose. Movies outside this interval are discarded.
A smaller percentage makes the protocol stricter and more sensitive to dose changes. A larger percentage is more permissive and may be preferable when small dose fluctuations are expected or when the estimate is noisy.
The default value is intended to detect clear dose inconsistencies without being overly sensitive to small fluctuations.
## Window Step
The Window step parameter controls how often the protocol evaluates whether there is a persistent dose anomaly over time.
For example, with a window of 50 movies, the protocol examines the most recent 50 dose estimates and calculates the fraction that fall outside the accepted dose interval.
This is useful because a single bad movie may not indicate a serious acquisition problem, whereas a long sequence of abnormal movies may indicate a persistent issue, such as a change in beam conditions, detector behavior, or recorded acquisition settings.
## Maximum Faulty Percentage
The Maximum faulty percentage parameter defines when a warning should be issued for a time window.
If the percentage of movies outside the accepted dose interval within the current window exceeds this threshold, the protocol writes a warning. This indicates that the dose anomaly may be persistent rather than isolated.
For example, if the threshold is 30%, and more than 30% of the movies in a window are outside the accepted dose interval, the protocol considers this a potential acquisition problem.
This parameter is mainly useful in streaming or chronological acquisition analysis, where changes over time are important.
## Accepted Movies
The outputMovies set contains movies whose estimated dose is within the accepted interval around the global reference dose.
These movies are considered dose-consistent according to the selected threshold. The output movies preserve the original movie information and also receive additional metadata fields describing the estimated dose statistics.
These accepted movies can be passed to downstream processing steps such as movie alignment, CTF estimation, particle picking, or reconstruction.
## Discarded Movies
The outputMoviesDiscarded set contains movies whose estimated dose falls outside the accepted interval.
A discarded movie is not necessarily unusable in all contexts. It means that its measured dose is inconsistent with the reference dose according to the selected threshold. The user should inspect discarded examples to determine whether the difference reflects a real acquisition problem, metadata error, detector artifact, or an overly strict threshold.
This output is useful for troubleshooting and for documenting possible acquisition instabilities.
## Metadata Added to Movies
For each evaluated movie, the protocol stores dose-related metadata, including:
the estimated mean dose per square angstrom;
the standard deviation of dose estimates across sampled frames;
the minimum and maximum estimated frame dose;
the percentage difference relative to the global reference dose.
These metadata help the user understand why a movie was accepted or discarded.
They can also be useful for later plotting, reporting, or correlating dose behavior with other quality indicators.
## Dose Analysis Plots
The protocol generates two diagnostic plots.
The first plot shows the estimated dose values over movie order, together with the global median and the upper and lower acceptance limits.
The second plot shows the percentage difference of each movie relative to the global reference dose over time.
These plots are useful for detecting trends. For example, the user may see a stable dose throughout acquisition, isolated outlier movies, or a sudden shift in dose after a particular point in the session.
Such temporal patterns can be very informative for facility quality control and for diagnosing acquisition problems.
## Streaming Behavior
The protocol supports streaming movie input.
As new movies arrive, the protocol processes them in batches, estimates their dose statistics, and updates the accepted and discarded outputs once the global reference dose has been established.
The output streams remain open while the input stream is open and are closed when all input movies have been processed.
This makes the protocol suitable for online monitoring during data collection. It can provide early warning if the dose becomes inconsistent during a session.
## Practical Recommendations
Use this protocol as an early quality-control step when dose consistency is important, especially in automated or streaming workflows.
Keep the default maximum percentage difference at first. If many apparently good movies are discarded, consider relaxing the threshold. If subtle dose changes are important for the project, consider using a stricter threshold.
Use enough samples to estimate a stable global median. Very small values may make the reference dose unreliable.
Inspect the dose-analysis plots rather than relying only on the accepted and discarded outputs. The plots can reveal temporal trends that are not obvious from individual movie decisions.
Pay attention to warnings about persistent faulty percentages within a window. A sustained dose anomaly may indicate a problem in the acquisition session.
Remember that this protocol evaluates dose consistency, not all aspects of movie quality. A movie can have correct dose but still be poor because of drift, contamination, bad ice, poor gain correction, or other problems.
## Final Perspective
Movie Dose Analysis is a quality-control protocol for detecting inconsistent electron dose across a movie dataset.
For biological users and cryo-EM facilities, it provides a practical way to separate dose-consistent movies from suspicious ones, monitor dose behavior over time, and detect possible acquisition anomalies early.
The protocol is especially useful in streaming workflows, where identifying dose problems during acquisition can help prevent large numbers of problematic movies from entering the downstream processing pipeline.
- PARALLEL_BATCH_SIZE = 8
- finished = False
- meanDoseList = []
- meanGlobal = 0
- medianDifferences = []
- medianDoseTemporal = []
- stats = {}
- usingExperimental = False