# * Authors: Carlos Oscar Sorzano (info@kinestat.com)
# *
# * Kinestat Pharma
# *
# * This program is free software; you can redistribute it and/or modify
# * it under the terms of the GNU General Public License as published by
# * the Free Software Foundation; either version 2 of the License, or
# * (at your option) any later version.
# *
# * This program is distributed in the hope that it will be useful,
# * but WITHOUT ANY WARRANTY; without even the implied warranty of
# * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# * GNU General Public License for more details.
# *
# * You should have received a copy of the GNU General Public License
# * along with this program; if not, write to the Free Software
# * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA
# * 02111-1307 USA
# *
# * All comments concerning this program package may be sent to the
# * e-mail address 'info@kinestat.com'
# *
# **************************************************************************
import pyworkflow.protocol.params as params
from .protocol_pkpd_sa_base import ProtPKPDSABase
from pkpd.models.sa_models import NCAEVModel
from pkpd.pkpd_units import PKPDUnit, strUnit
from pyworkflow.protocol.constants import LEVEL_ADVANCED
# TESTED in test_workflow_gabrielsson_pk06.py
[docs]class ProtPKPDNCAEV(ProtPKPDSABase):
""" Non-compartmental analysis of a non-intravenous bolus.\n
Protocol created by http://www.kinestatpharma.com\n"""
_label = 'nca ev'
#--------------------------- DEFINE param functions --------------------------------------------
def _defineParams(self, form):
form.addSection('Input')
form.addParam('protAbsorption', params.PointerParam, label="Non-IV Input experiment",
pointerClass='ProtPKPDAbsorptionRate', important=True,
help='Select an execution of a protocol estimating the absorption rate.')
form.addParam('areaCalc', params.EnumParam, choices=["Trapezoidal","Mixed"],
label="Method for AUC, AUMC calculation", default=1, expertLevel=LEVEL_ADVANCED,
help='The mixed integration uses the trapezoidal is used in the raising side and the log-trapezoidal in the decay side.\n'
'See explanation at http://learnpkpd.com/2011/04/02/calculating-auc-linear-and-log-linear\n')
form.addParam('protNCAIV', params.PointerParam, label="IV Input experiment (optional)", allowsNull=True,
pointerClass='ProtPKPDNCAIVExp,ProtPKPDNCAIVObs',
help='A companion experiment with intraveneous bolus is used to estimate the bioavailability and the Mean Absorption Time. '
'The sample names in both experiments must be exactly the same.')
#--------------------------- STEPS functions --------------------------------------------
[docs] def getXYvars(self):
self.varNameX = self.protAbsorption.get().protElimination.get().predictor.get()
self.varNameY = self.protAbsorption.get().protElimination.get().predicted.get()
[docs] def createAnalysis(self):
self.analysis = NCAEVModel()
self.analysis.setExperiment(self.experiment)
self.analysis.setXVar(self.varNameX)
self.analysis.setYVar(self.varNameY)
self.analysis.F = self.protAbsorption.get().absorptionF.get()
if self.areaCalc == 0:
self.analysis.areaCalc = "Trapezoidal"
elif self.areaCalc == 1:
self.analysis.areaCalc = "Mixed"
[docs] def prepareForSampleAnalysis(self, sampleName):
sample = self.experiment.samples[sampleName]
sample.interpretDose()
self.analysis.D = sample.getDoseAt(0.0)
self.analysis.Ke = float(sample.descriptors["Ke"])
return True
[docs] def postAnalysis(self, sampleName):
if self.experimentIV!=None:
if sampleName in self.experimentIV.samples:
sampleNIV = self.experiment.samples[sampleName]
DNIV= self.analysis.D
sampleIV = self.experimentIV.samples[sampleName]
sampleIV.interpretDose()
DIV = sampleIV.getDoseAt(0.0)
F = float(sampleNIV.descriptors['AUC_0inf'])/float(sampleNIV.descriptors['AUC_0inf'])*DIV/DNIV
MAT = float(sampleNIV.descriptors['MRT']) - float(sampleIV.descriptors['MRT'])
self.experiment.addParameterToSample(sampleName, "F", PKPDUnit.UNIT_NONE, "Estimated bioavailability", F)
self.experiment.addParameterToSample(sampleName, "MAT", self.analysis.parameterUnits[-1], "Estimated Mean Absorption Time", MAT)
print("F = %f"%F)
print("MAT = %f [%s]"%(MAT,strUnit(self.analysis.parameterUnits[-1])))
#--------------------------- INFO functions --------------------------------------------
def _summary(self):
msg=[]
msg.append("Non-compartmental analysis for the observations of the variable %s"%self.protAbsorption.get().protElimination.get().predicted.get())
return msg
def _warnings(self):
experiment = self.readExperiment(self.getInputExperiment().fnPKPD,show=False)
incorrectList = experiment.getNonBolusDoses()
if len(incorrectList)==0:
return []
else:
return ["This protocol is meant only for intravenous bolus regimens. Check the doses for %s"%(','.join(incorrectList))]